The Medical Equipment Exhibition (MEDICA) in Dusseldorf, Germany is a world-renowned comprehensive medical exhibition, recognized as the world's largest hospital and medical equipment exhibition, and ranks first in the world's medical trade exhibition with its irreplaceable scale and influence. As a flagship exhibition in the global medical technology and innovation field, with its huge scale, extensive international exhibitor and purchaser network, cutting-edge medical technology and product display, and in-depth industry exchange and cooperation platform, it not only profoundly shapes and leads the trend and direction of the global medical device market, but also becomes an important force in promoting the progress and development of the global medical industry with its authority and unparalleled influence in the field of medical technology.
Dual core dual cylinder dehydration system

The T/ST intelligent dehydration platform system adopts advanced control technology and precise temperature and pressure regulation system, significantly improving the dehydration effect of pathological tissues. This innovative technology ensures the minimization of tissue damage and maintains the integrity and structure of cells.
Intelligent dual cylinder design
T/ST has achieved the first parallel operation of multiple programs on a single instrument, providing optimal dehydration conditions for various tissue types. Its dual cylinder structure allows for the simultaneous processing of up to 450-1500 samples, which increases the operating capacity by 50-400% compared to traditional single cylinder tissue dewatering machines with 300 embedded boxes.
Dual core system guarantee
The dual core design of T/ST includes dual gas and liquid circuits, dual pumps and valves, dual operating systems, etc., ensuring the continuous and efficient operation of the equipment. This system not only enhances the stability of the equipment, but also effectively guarantees the quality and safety of the samples through a redundant backup system.
Ultra low temperature freezing embedding system
- Frozen assistant for fat and vertically cut tissue
Freezing embedding instrument

Efficient freezing technology
Sterling Technology: Quickly reaching the cooling point, greatly reducing freezing time and improving slicing efficiency.
Facedown technology: ensures fast and standardized preparation of organizational blocks, significantly reduces repair time, and improves overall workflow efficiency
High quality slicing guarantee
Reduce ice crystal formation: The unique freezing mechanism effectively reduces the formation of ice crystals, ensuring the clarity and integrity of the slices.
Improving slice quality: Optimized freezing process makes slices smoother and crack free, providing accurate basis for pathological analysis.
Flexible adaptation and wide application
6-slot/12 slot selection: Meet different experimental needs and flexibly respond to laboratory operations of various scales.
Compatible with 20/30/35/40mm freezer heads: Widely compatible with various specifications of freezer heads, suitable for various experimental scenarios.
Environmentally friendly economy, zero cost use
No additional use of dry ice, liquid nitrogen, or refrigerants is required, which is not only environmentally friendly but also cost-effective, achieving true zero cost use.
Number machine series

Efficient, smooth, and high-quality slicing experience
X7 Elite semi-automatic paraffin slicer

Frozen embedding agent

Performance characteristics
1. Freeze quickly, causing minimal damage to crystal formation;
2.It can achieve rapid dehydration, transparency, wax immersion, and embedding functions, with the same effect as conventional paraffin sections;
3.No need to remove from the slice, it will dissolve in aqueous solution during staining;
4.Can be used as an infiltrative solvent for cutting easily ruptured tissues, such as the brain.
Xiuwei frozen head

Xiuwei freezing head, suitable for various brands of frozen slicing machines
The freezing head is an indispensable tool in frozen slicing, but due to frequent contact with the slicer, it may gradually wear out or even be damaged. In addition, to avoid cross contamination between different samples, it is best to use a new freezing head for each sample. This ensures that the processing environment for each sample is clean and independent. Therefore, if any problems are found with the freezing head or doubts about the quality of the slices during use, they should be replaced in a timely manner.
Manual chip gun-XW-1027
1. The world's only patented technology with embedded box receptor wax block, which does not require embedding after implantation; 2. Obvious comparison, reducing error rate; 3. The diameter of the sampling needle and the number of wax block holes can be customized as needed; 4. The receptor wax block can be used in conjunction with any manufacturer's tissue chip analyzer; 5. The operation steps are simple, only requiring three steps (pick plant push). | ![]() |